Your servers sit on Istanbul's European side, near the TEM and Basın Ekspres highways, in halls designed to the EN 50600 European data center standard.

- N+2
- Redundant power
- A + B
- Dual feeds to every rack
- 18–24 °C
- Cold aisle
- 24/7
- Security and monitoring
Infrastructure
Redundant from end to end
From power to cooling, from fire to security, every system is built to keep running when one of its components is out.
Power
N+2 redundant power. Every rack gets two separate feeds, A and B; modular UPS and automatic generator transfer keep a grid failure away from your servers.
Cooling
Hot and cold aisles are fully separated. Redundant cooling units hold the cold aisle at 18–24 °C at all times.
Environment monitoring
Temperature and humidity are measured continuously; operations are alerted the moment a threshold is crossed.
Fire suppression
A NOVEC 1230 clean-agent system backed by early-warning sensors. No residue, non-conductive, harmless to hardware.
Access control
Biometric access, multi-factor authentication and mantrap entries; only authorised people enter the hall.
CCTV and perimeter
The inside and the perimeter of the facility are watched by recorded CCTV around the clock.
Location
On the European side, close to your team
The facility is in Mahmutbey, Bağcılar, a few minutes from Istanbul's main traffic arteries. It is easy to reach from the city for a hardware delivery, an installation day or an urgent repair.
Istanbul is where Türkiye's carrier backbones and internet exchange points meet. Hosting here means reaching most of your users over the shortest network path.
- Address
- Mahmutbey, Bağcılar
- City
- Istanbul, European side · Türkiye
- Visits
- By appointment
- Technical tours by appointment
- On-site support on installation day
- Hardware accepted by courier
- Remote Hands for work from afar

Operations
On-site support
Remote Hands
Swapping a cable, inserting a disk, a reboot, checking LEDs or a screen: none of it needs you on site.
Mounting and cabling
Ship your hardware or bring it in; our team mounts it and does the A+B power and network cabling.
Announced maintenance
Planned maintenance is announced in advance and scheduled for low-traffic hours wherever possible.
Meet-me room
Türk Telekom, Vodafone and GibirNet hand-offs are inside the facility, one patch cable away.
Standards
The standards the facility is designed and run to
- EN 50600
- European data center standard. Redundancy and concurrent maintainability in facility and infrastructure design.
- ISO 27001
- Information security. A risk-based control framework for information security management.
- ISO 9001
- Quality management. A quality standard built on process improvement and customer satisfaction.
- ISO 27017
- Cloud security. Information security controls specific to cloud services.
- KVKK
- Data protection. Legal compliance for processing and storing personal data in Türkiye.
- NOVEC 1230
- Fire suppression. Automatic clean-agent suppression with sensor-based early fire detection.
Questions about the facility
Can I visit the data center?
Yes. We arrange technical tours by appointment for anyone who wants to see the facility before deciding. On the tour you can see the power plant, the cold aisles and the security process for yourself.
What happens to my servers in a power cut?
The load moves to UPS the moment the grid fails, and generators then start automatically. Because racks are fed by two separate lines, A and B, dual-PSU servers are not affected by a problem on one line.
Can I access my server physically?
Yes. Your authorised staff can come to the data center by appointment. Day-to-day work is remote; when hands are needed on site, our Remote Hands team steps in.
How do I deliver my hardware?
Ship it by courier or hand it over at the data center. Our team does the mounting and cabling; full-rack customers may do the installation with their own staff if they prefer.
Does the fire suppression system harm hardware?
No. NOVEC 1230 is a clean agent: it leaves no residue and does not conduct electricity. Unlike water or powder systems, it does not damage running equipment.
Would you like to see the facility in person?
Book an appointment and we'll walk the halls together, or calculate your price right away.